Any ACD detector with at least one PMT reaching zero suppression threshold, aka low threshold, aka 0.1 MIPs is stored on the TDS and ultimately in the output ROOT files - this collection forms the AcdDigiCol.
Please note that TriggerAlg was recently updated (as of v4r3p2) such that veto threshold (0.3 MIP default) is utilized in determining ACDLO in the GltWord. This modification was not included in DC2 as agreed

Status

Fiber attenuation on a per PMT basis was achieved in time for DC2.

To Do:

  • Ribbon Attenuation
    Alex has provide mean PE per MIP for an average ribbon at various positions.
  • What plans are there to store mean PE per MIP per PMT as a calibration? Values from GSFC tests are currently stored in XML in the AcdDigi package.
  • Revisit CNO calculation.
  • Revisit noise calculation.
  • Implement readout limitiations - accept and hit maps contain enough bits for 18 channels.Fiber attenuation
  • Utilize the AcdGeometrySvc throughout digitization and reconstruction for consistency.

...

*AcdTkrIntersection
*AcdHit collection
AcdDigis with added calibrated MIP values per PMT
*AcdPoca
Eric's talk from Dec 16 2005

To Do:

  • ACD Calibration Service
    Seem to be questions revolving around what gets stored and where.
  • Remove old DOCA and original Active Distance calculations and their ntuple entries.
    What does this mean? We will eliminate the following summary ntuple variables: AcdDoca, AcdDocaTileEnergy, AcdGammaDoca and their siblings located in the recon.root files.
  • Add TkrIntersection quantities to the summary ntuple
  • Should check that what has propagated into SVAC ntuple has a cousin in the summary ntuple if desired.
  • Update Ribbon Active Distance calculation

...