Meeting notes

Questionnaire

Motors (standard):

  • Target manipulator - meaning large hexapod?
  • Standard SPL beam delivery motorization
  • OAP will also be motorized
  • MXI assembly
  • XTCS or XRTS spectrometer (tbd)

Motors (new):

  • Special motorization for focus diagnostic

Cameras:

  • Alvium for focus diagnostic
  • Alvium for NF/FF
  • Alvium for time tool instrument

From 18 March 2025 CDR:

Camera inventory

  • Zyla for MXI
  • standard alvium for near-field/far-field and time-tool
  • alvium in vacuum for electron spectrometer
  • optional: discussion on XTCS use not completed → potentially ePix100a


Data access

  • psana access should be preferred (no need for tiff conversion)

 

Motorization

  • work on the MXI virtual motor is needed
  • std. motorization: zyla stage, MXI, target manipulator, SPL platforms, time-tool
  • new OAP motorization should reuse the usual PI xyz assembly
  • new focus diagnostic should use UTS or PLS85 + 2 MFA + UMR with LTA?
    • UTS + 2 MFA

As-Built

Newport Configuration:

tch1tch2tch3tch4

1 Questar 1 H  

9 SPL M5 Tip (DB25) B7/H1 - OK

17 TSO Vert - OK

25

2 Questar 1 V 

10 Patch Panel Blanked Off

18 TSO foc - OK

26 

3 Questar 2 H11 SPL M5 Tilt (DB25) B7/H3 - OK

19 

27 


4 Questar 2 V 12 TSO Focus (DB25) B5/B3 - OK

20 FSSR Foc - OK

28

5 BED 2

13 Patch Panel Cable Mount Bad

21 

29


6 BED 1

14  

22 


30 


15 XTCS Linear (DB15) B7/H4 - OK.

23 TSO hor - OK

31 New Rotation Stage (DB15) T5/1 - OK

16 XTCS Rotation (DB15) B7/H8 - OK. Note: I had difficulties with air-side connecting on H6.24 Zyla 500 mm (air) - OK

32 


IMS Configuration:

Notes

  • We have two types of air-side DB15F - TT19P cables, both labled XTCS Filter Wheel. We need to relabel.
  • Use the black in-vac extension cables, not the pink/white ones. Categorize and label.
IMSFFStatusIMSFFStatus
PR60 1: USR 17

TgX

pmgr: PLS-85 In-Vac


OK

PR60 2: 



PR60 3: USR 19

T5/5 DB15

pmgr:VT-50-100-L

Ref laser goes here 

OK


PR60 4: USR 20

T5/#4 DB9

pmgr: Vacuum Iris

Vacuum Iris goes here

OK

PR60 5: USR 21

T5/4 DB15

pmgr: VT-50-100-L

changed UREV from 1.0 to 0.5.

Filter goes here

OKPR60 6: USR 22

T6/12 DB15

pmgr: XUV Filter Pos

Vac Cable: 12 "Filter Wheel"

T6/12

Air Cable: MEC:TC1:MMS:22

OK

PR60 7: USR 23

T5/2 DB15

pmgr: VT-50-100-L

Power meter goes here

OKPR60 8: 

PR60 9: USR 25

OAP X

pmgr: XUV X, % RC changed from 10 to 30 

Vac Cable: MEC:USR:MMS:22

Black vac extension cable

T5/8

Air Cable: MEC:USR:MMS:22


OKPR60 8: USR 26

OAP Y

pmgr: FWD XRTS Y

Vac Cable: Direct connection to FF

B7/H9

Air Cable: MEC:TC1:MMS:23  

OK

PR60 11: USR 27

T5/#1 DB9 

pmgr: AFW-65

Micos Filter Wheel

Note: Use of Filter Wheel air side cable is required!


OKPR60 12: USR 28


BAD CHANNEL

PR60 13



PR60 14

PR60 15: TC1 22

pmgr: MXI Z Stage

Vac Cable: Direct connection to FF

B5/B6

Air Cable: MXI Z

OK



PR60 16: TC1 23

OAP Z

pmgr: XUV X, % RC changed from 10 to 30 

Vac Cable: MEC:USR:MMS:25

Black vac extension cable USR 25

T5/3

Air Cable: MEC:USR:MMS:25

OK


MEC:TC1:MMS:{07-09}

D2c/D10 DB50

pmgr: XUV Z/Y/X

OK










Component Summary

ComponentItemPVOperational
Zyla500mm MEC:PPL:MMN:24Y
MXIZ stageMEC:TC1:MMS:22Y
XTCSLinearMEC:PPL:MMS:15Y

RotationMEC:PPL:MMS:16Y

Filter WheelMEC:USR:MMS:22N For Tuesday
Vacuum Iris
MEC:USR:MMS:20Y
SPL Ref Laser
MEC:USR:MMS:19Y
SPL M5TipMEC:PPL:MMN:09Y

Tilt

MEC:PPL:MMN:11


Y
FilterXMEC:USR:MMS:21Y
Power Meter Stage
MEC:USR:MMS:23Y
Micos Filter WheelFor viewport and alvium_spl_spot protection.MEC:USR:MMS:27

Y

OAPXMEC:USR:MMS:25

Y


YMEC:USR:MMS:26

Y


ZMEC:TC1:MMS:23


(TSO) Focushor UTSMEC:PPL:MMN:23

Y


vert MFA 1 MEC:PPL:MMN:17

Y


focus MFA 2MEC:PPL:MMN:18

Y

New Rotation Stage
MEC:PPL:MMN:31

Y

FSSR Focusfor epix100a_2_fssrMEC:PPL:MMN:19

Y


Detectors

WhatConnectionStatus
Zyla

standard in-air

daq-mec-cam03

Y
epix100 XTCS

standard

daq-mec-cam01

Y as epix3, damages as epix1

epix10k Q3

standard

daq-mec-pgp02

Y
Alvium Spot

04K7Y (1236m)  

Shutter 4 platform

daq-mec-cam05

Y

Note: 04KZX (2040m) damages, other two 2040m already SPL damaged.

Alvium Timetool

04K7T (291m)

daq-mec-cam03

Y
Alvium NF/FF

04K7W (1236m)

daq-mec-cam05

Y
X-Ray Power Meter

Into R62 User Beckhoff.

MEC:USR:AIN:1