Motor Checklist
| Purpose | Base PV | Connection | pmgr | python device | Cabled? | Verified/Homed? |
|---|---|---|---|---|---|---|
| Standard Motors | ||||||
| MXI | ||||||
| MXI Hexapod | MEC:HEX:02 | Flange T3 to Hexapod 2 controller top of target chamber. | N/A | Yes | Yes | |
| MXI linear stage | MEC:USR:MMS:21 | Micronix PPS-110 stage to Flange B7/H<tbd> to PR60 patch panel MEC:USR:MMS:21 connection | Crystal Y | |||
| Zyla 500 mm linear stage | MEC:PPL:MMN:24 | In-air Direct cabling to XPS3, Card #8 | Newport | Yes | Yes | |
Other Devices Checklist
| Purpose | Base PV | Connection | Cabled? | Operational? |
|---|---|---|---|---|
| Permissive Signal | ||||
| Trigger | MEC:USR:AIN:9 | User timing and firing unit permissive output (+5V 100 microsec pulse) to R62 EK9000, second KL3404 (card 11), first channel, PV MEC:USR:AIN:9. KL3404 specs are "4-channel analog input, voltage, ±10 V, 12 bit, single-ended" May need pulse extended, e.g. with a function generator, for detection by PLC. | Yes | |
Detectors Checklist
| Detector | DAQ alias | Connection | Cabled? | In DAQ? |
|---|---|---|---|---|
| epix10k-540k | quad_0 | in-air Power: Fiber: | ||
| epix10k-540k | quad_1 | in-air Power: Fiber: | ||
| epix10k-549k | quad_2 | in-air Power: Fiber: | ||
| epix10k-540k | quad_3 | in-air Power: Fiber: | ||
| Andor Zyla | zyla | in-air USB/Fiber extender to daq-mec-cam02 | Yes | Yes |