Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

facet home → Profile Monitor → LI20 → SPEC LINE GUI

New SPECLINE GUI (Fall 2023):

Image AddedImage Removed

  • Leave big "Dipole" switch in "Without" setting (dipole energy is not adjusted)
  • Set "Z Object" to the position where the beam should be imaged, e.g., the center of the PB
  • Set "Z Image" to the position of the screen, e.g., z=2015.26 for DTOTR
    • Note: You can select from a few preassigned beamline locations with the dropdown menu, or, select "custom"
  • M12, M34: transfer-matrix elements (set both to 0 for re-imaging)
  • Energy: determines where the focus is
  • Press "Calculate and Trim"
  • ATTENTION: there is no possibility to calculate without actually changing the magnets. There will be no elog entry! (2023, Nov 17)
  • Note - the "Trim" button does not do anything yet.


Dump table motors and filters:

IP2 Table on LI20 Profile monitor page:

Image Added

Provides easier access to the dump table flippers (DTOTR1/2, LFOV) and motors.


Scripts for dealing with the spectrometer

...