Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Assume DEVICE = TGAL:SYS0:00for linac locking.  An alternative  Alternatives could be DEVICE = LLO:SYS0:00 (Linac Locking Osc) orDEVICE = LLTA:SYS0:00 (LLTA: Linac Locking Trigger Alignment).

PV NameRecord TypeDESCFunctionality

$(DEVICE):FWVER

longin

Firmware version number


$(DEVICE):NCLINKUP

bi

NC timing link up


$(DEVICE):NCFIDCNT

longin

NC timing fiducial count


$(DEVICE):NCERRCNT

longin

NC timing error count


$(DEVICE):NCINTVERRCNT

longin

NC interval error count


$(DEVICE):NCCLKFREQ


longin

NC clock rate


$(DEVICE):SCLINKUP


bi

SC timing link up


$(DEVICE):SCFIDCNT


longin

SC timing fiducial count


$(DEVICE):SCERRCNT


longin

SC timing error count


$(DEVICE):SCINTVERRCNT


longin

SC interval error count


$(DEVICE):SCCLKFREQ


longin

SC clock rate


$(DEVICE):NCREFCNT


longin

NC timing reference count


$(DEVICE):SCREFCNT


longin

SC timing reference count


$(DEVICE):TMOCNT


longin

Measurement timeout count


$(DEVICE):DIFFCLOCKS


longin

Timing reference difference, clocks


$(DEVICE):DIFFPHASE


ai

Timing reference difference, phase


$(DEVICE):DIFFPHASEN


ai

Timing reference difference, phase compl


$(DEVICE):NCTRIGDELAY

longout

NC trigger output delays


$(DEVICE):RXMODE

longout

NC source