Run " meclas.HWP.HWP_opt()". You can alsorun one or two arms by " meclas.HWP.HWP_opt(armsQ='ABIJ)".

Fire a shot

  • Make sure the final shutter, T3a and T3b, are closed. If it is open, make sure

...

  • things are properly blocked inside the target chamber.
  • check event sequence configuration: play status "stopped" in case the lamps got misfired.
  • change camera trigger to "single shot": in MEC Home> EVR > New MEC LAS EVR > Front Panel B change to 182 (single shot) from 43 (10Hz)
  • change Ns Slicer and Lamps to single shot: Long pulse laser operation> click Single buttons on NsSlicer and Lamps
  • Charge: MEC:PFN> click "stop", "Stand By", "Ready" and "Charge"
  • Fire: click "single shot"
  • run postshot: "meclas.LPL.pspostshot(save_flag = True, display = True)" it shows a plot and energy output.
  • or show energy meter: "meclas.EMeters.Gall()"

Image Added

...