Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

When changing cameras, be sure to enable or disable its corresponding IOC using iocmanager

ChambercamViewer name Gige name CameraHostBuildIOC Manager AliasIOC Name
SC1 on-axis cxi_sc1_inline
Opal 1000-mioc-cxi-rec03rhel5rhel7CAM - SC1 Inline Questar Opal1000mioc-cxi-sc1-inline
SC1 off-axiscxi_sc1_offaxis
Opal 1000-mN/AN/AN/Aioc-cxi-rec04rhel7CAM - SC1 Offaxis Questar Opal1000mioc-cxi-sc1-offaxisN/A
SC1 Navitarcxi_sc1_navitargige-cxi-navitar1Gige Mako G319Cioc-cxi-cam2rhel7CAM - SC1 Navitar Gigeioc-cxi-navitar1-gige
SC2 on-axiscxi_sc2_inlinegige-cxi-06Gige Manta 146Cioc-cxi-rec04wave8rhel7CAM - SC2 Inline Gige 06ioc-cxi-sc2gige-inline06
SC2 off-axiscxi_sc2_offaxisgige-cxi-07Gige Mako G319C N/AN/AN/AN/Aioc-cxi-rec03rhel7CAM - SC2 Offaxis Gige 07ioc-cxi-gige-07
SC2 NavitarNANANANANANANASC2 Navitar
SC3 on-axiscxi_sc3_inlinegige-cxi-05Gige Manta 146Cioc-cxi-rec04rhel7CAM - SC3 Inline Inline Gige 05ioc-cxi-sc3gige-inline05
SC3 off-axiscxi_sc3_offaxisgige-cxi-03Gige Manta 146Bioc-cxi-rec03rec04rhel5rhel7CAM - SC3 GigE Offaxis Gige 03ioc-cxi-gige-03
Timetoolcxi_timetoolgige-cxi-timetoolGige Mako G319Cioc-cxi-cam5rhel7CAM - Timetool Gigeioc-cxi-timetool-gige
DG1 Yagcxi_dg1_yaggige-cxi-dg1Gige Manta 146Cioc-cxi-rec01rhel7CAM - DG1 PIM Gige 01ioc-cxi-dg1-gige
DG2 Yagcxi_dg2_yaggige-cxi-dg2Gige Manta 146Cioc-cxi-rec01rhel7CAM - DG2 PIM Gige 02ioc-cxi-dg2-gige
DG3 Yag

Gige Manta 146Cioc-cxi-rec03rhel7CAM - DG3 PIMioc-cxi-dg3-p6740


Gige Debugging tips: 

To check if the camera is online and if the camera is a gige, then it should be pingable on the network. Use the name from column #3 from the above table, "Gige name" to check if the camera is seen by the cds network. Example: ping gige-cxi-timetool. 

camViewer:

To open the camera with camviewer, use name from column #2 "camViewer name", Example : camViewer -c cxi_timetool

When a new camera is added or changed and a new IOC is deployed, the camviewer configuration file needs to be changed to make the new camera viewable in the camViewer.  Comment out the line from the previous camera and uncomment or create a new entry for the camera.  The camviewer configuration file can be found be found at /reg/g/pcds/pyps/config/cxi/camviewer.cfg.

...