Full source code can be found here. It can be run natively on unix systems using the Local PyDM/Simulacrum Setup instructions |
...
Full Procedure
SSA Calibration
- Set the drive max to the previously saved drive max found during initial cavity commissioning (or 1 for the the harmonic linearizers)
- Recursively run an SSA calibration with decreasing drive max until either the calibration succeeds or it hits one of two fault conditions:
- The max forward power is less than 3kW
- The desired drive max is less than 0.5
...