Room 208 Fiber Connections
See FEE Alcove Fiber Cabling for description of which patch panel in 208 goes to which detector. Note that the fiber numbering on that page is different from here. On the FEE alcove page we number fibers left-to-right, then top-to-bottom. Here we use a better scheme: using the actual fiber numbers marked on the cassettes. We should convert the FEE-alcove page to use the better scheme.
Source | Destination | Notes |
---|---|---|
ATCA crate fiber port 0 | LC cassette 4 (counting from 1, left to right) fibers 11/12 | 10Gb network to SRCF node (drp-srcf-cmp004?) |
XPM 2 input on RTM comes | Rack 4 in TMO hutch, FODU2, Cassette 4, fibers 3-4 (2.4.3-4) | |
Output of XPM2 in 208 | TMO FODU 1, Cassette 3, Fibers 17-18: 1.3.17-18 | Cassette 1 is missing |
Output of XPM3 in 208 | RIX FODU 1, Cassette 1, Fibers 7-8: 1.1.7-8 | |
XPM0-AMC0-PORT0 | RIX 1.1.3-4 | This is XMP0 → XPM3 in RIX, FODU 1 for RIX is FODU 5 in 208 |
XPM0-AMC0-PORT1 | TMO 2.4.3-4 | This is XMP0 → XPM2 in TMO, FODU 2 for TMO is FODU 7 in 208 |
XPM5-AMC0-PORT0 | RIX 1.1.3-4 | This is XPM3→ XPM5 |
XPM6-AMC0-PORT0 | TMO 1.3.17-18 | This is XPM2→ XPM6 |
TMO ATM CAMLINK | TMO FODU 1 cassette 3 fiber 1-2 (a.k.a. 1.3.1-2) | cassette 1 is missing |
XPM Topology
Code Block |
---|
globalTiming -> newxpm0 -> 2 (tmo) -> 4 (tmo) -> 6 (208) -> BOS -> 3 (rix) -> 5 (208) -> BOS |
...