  • bos: 320 pairs, 160 for detectors, 160 for srcf
  • nodes: 56*8=448 pairs
  • fibers between 208 and srcf: 300 fiber pairs (75% MPO, 25% LC?)

SRCF Fiber Order

55
Image ModifiedFS QSFP-PLR4-40G Compatible 40GBASE-PLR4 QSFP+ 1310nm 10km DOM MTP/MPO-12 SMF Optical Transceiver Module

 (singlemode plr4 qsfp)
25 
Cisco QSFP-40GE-LR4 Compatible 40GBASE-LR4 QSFP+ 1310nm 10km DOM Duplex LC SMF Optical Transceiver Module (single mode lr4)
45 
Cisco CVR-QSFP-SFP10G Compatible 40G QSFP+ to 10G SFP+ Adapter Converter Module (sfp to qsfp adapter) CVR-QSFP-SFP10G
60 
Cisco SFP-10G-LR Compatible 10GBASE-LR SFP+ 1310nm 10km DOM Duplex LC SMF Optical Transceiver Module (singlemode sfp transceiver (for sfp-to-qsfp adapters))
25 
3m (10ft) MTP® Female to 4 LC UPC Duplex 8 Fibers Type B Plenum (OFNP) OS2 9/125 Single Mode Elite Breakout Cable, Yellow (3m singlemode breakout)
20 
1m (3ft) MTP® Female to 4 LC UPC Duplex 8 Fibers Type B Plenum (OFNP) OS2 9/125 Single Mode Elite Breakout Cable, Yellow (1m single mode breakout)
45 
Customized 8-144 Fibers Senko MPO-12 OS2 Single Mode Elite Trunk Cable, Yellow (3m mpo12 trunk cable)
20 
0.5m (1.6ft) LC UPC to LC UPC Duplex OS2 Single Mode PVC (OFNR) 2.0mm Fiber Optic Patch Cable (0.5m patch fiber)
20 
1m (3ft) LC UPC to LC UPC Duplex OS2 Single Mode PVC (OFNR) 2.0mm Fiber Optic Patch Cable (1m patch fiber)
20 
1.5m (5ft) LC UPC to LC UPC Duplex OS2 Single Mode PVC (OFNR) 2.0mm Fiber Optic Patch Cable (1.5m patch fiber)
20 
2m (7ft) LC UPC to LC UPC Duplex OS2 Single Mode PVC (OFNR) 2.0mm Fiber Optic Patch Cable (2m patch fiber)
20 
3m (10ft) LC UPC to LC UPC Duplex OS2 Single Mode PVC (OFNR) 2.0mm Fiber Optic Patch Cable (3m patch fiber)
10 
4m (13ft) LC UPC to LC UPC Duplex OS2 Single Mode PVC (OFNR) 2.0mm Fiber Optic Patch Cable (4m patch fiber)

Sept. 2022 Cabling Proposal

...

  • tmo timing (including pvadet, bld) (LC, SFP to QSFP)
  • rix timing (LC, SFP to QSFP)
  • (4) tmo camlink nodes (LC, needs timing)
  • (2) rix camlink nodes (LC, needs timing)
  • tmo/rix fim node (5 fims) (MPO, PLR4)
  • (2) rix hsd nodes (2 LC per node, LR4)
  • (7) tmo hsd nodes (2 LC per node, LR4)
  • peppex hsd node (LC LR4)
  • (2) tmo/rix ami
  • (2) tmo/rix teb
  • (2) tmo/rix mebuser
  • xtcav (LC, needs timing)
  • mono-encoder (LC, needs timing)
  • in SRCF:
    • let's try MPO for all the timing/tdet (this may be wrong)
    • tdet (12, timing): SFP fiber (from an MPO breakout cable) SFP to QSFP converter
      • 3 MPO breakout, 12 SFP to QSFP converters, 12 SFP transceivers
    • ilv (10, hsd): SFP fiber with LR4 transceiver (no MPO)
      • 20 LC, 20 LR4
    • wave8 (1, XilinxKcu1500Pgp4_6Gbps_ddr): MPO fiber with PLR4 transceiver
      • 1 MPO, 1 PLR4
    • camlink (4, ClinkKcu1500Pgp2b): data (transceiver 0, up to 4 lanes/cameras) MPO fiber with PLR4, timing (transceiver 1), try MPO fiber with PLR4 (neater, but wastes fibers)
      • 8 MPO, 8 PLR4

current inventory (sept. 13, 2022):

...