Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • binVar_bins: bin edges as defined in the config or the default (unique) motor positions. In the latter case, the first value is NaN, as a bin is manually added to catch outliers on the left for the general case.
  • nEntries: number of shots in each bin
  • binVar: sum of the binned variable. When binning linearly, binVar/nEntries should return the most accurate position. A field with the binned variable name contains the same information.
  • All the binned variables defined in varList: for the regular detectors (non-area detectors) the syntax follow that of the varList, where / have been replaced by __ (two underscores). Binned area detectors images or calib are under <detname>_data. A <detname>_nEntries field should match the nEntries field. If not, contact your controls and data PoC.
    Example from the config file above:
    • ipm2__sum
    • ipm3__sum
    • diodeU__channels
    • jungfrau1M_data
    • jungfrau1M_nEntries
  • A config entry for each area detector: <detname>_cfg that contains the detector config (pedestals, gain map, mask, etc.)