The configuration consists of the following main points sections (see example below too):

  • Custom bin definition: Using a run-based logic, one can define how to bin the data here. If no bins are given for a run, then the unique position of the corresponding scan motor will be used. The former is typically used for time or energy fly-scans and the latter is recommended for regular motor scans, such as phi or laser lens scans.
  • Filter definition: Default filter name is filter1. Any other filter name will lead to the creation of separate cube files ending with _filtername. This can be useful in case where an external field is applied on certain shots for example.
  • Laser on/off: If True will create _on and _off cubed file.
  • Detectors: Area detectors dictionaries to be cubed are defined here. Different argument are available:
    • Pixel intensity threshold: thresADU (float)
    • Common mode selection: common_mode
    • Whether to return the image or the individual tiles (calib): image (True / False)
    • Not-implemented (ignore for now): full
  • All the variable to add to the cubed file are then added to varList. The syntax for each non-area detector variable should follow the structure in the smalldata h5 file. Area detectors dictionaries must be added to this list as well.
  • Histograms: At the end of the cube, a summary is posted to the elog. A list of variables can be customized here. The IPMs and timing tool are generally considered default. If a variable is also in the filter list, the filter boundaries will be shown in the histogram too. The pixel histograms for the area detector defined are also included in the summary. These plots can help you choose relevant filters and thresholds.

...