Info | ||
---|---|---|
| ||
If the trigger signal is disconnected from the camera, the IOC will continue to report that the camera is connected but will stop acquiring images! If a camera is not triggering properly, verify that there are no connection interruptions between the host and the camera and take a look at the camera's sync settings on its expert screen. |
(Screenshot of expert screen)
...
Info | ||
---|---|---|
| ||
If you are setting up a GigE at the sample chamber and cannot find a CDS PoE ethernet port on the patch panel because none of the ports are labeled properly, senselessly harass the nearest PCDS engineer. |
When changing cameras, be sure to enable or disable its corresponding IOC using the iocmanager.
Chamber | Camera | Axis | Host | IOC Alias | IOC Name |
---|---|---|---|---|---|
SC1 | Opal 1000-m | On | ioc-cxi-rec03 | CAM - SC1 Inline Questar Opal1000m | ioc-cxi-sc1-inline |
SC1 | Opal 1000-m | Off | N/A | N/A | N/A |
SC2 | Opal 1000m | On | ioc-cxi-rec04 | CAM - SC2 Inline Questar Opal1000m | ioc-cxi-sc2-inline |
SC2 | Manta 146C | Off | N/A | N/A | N/A |
SC3 | Opal 1000m | On | ioc-cxi-rec04 | CAM - SC3 Inline Questar Opal1000m | ioc-cxi-sc3-inline |
SC3 | Manta 146C | Off | ioc-cxi-cam2 | CAM - gige 07 | ioc-cxi-gigE-07 |
SOME INFO ABOUT PREFERED SETTINGS FOR THE CAMERAS.
...