Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

17:00 Controlled access to rotate the RD53A module.

18:19 Access complete. RD53A rotated so display cables plugged in from the top.

18:21 Beam back on

 

Run NumberStart timeEnd timeNumber of EventsWindow coordinates (DUT)Comments
142

03/06/18

18:24

03/06/18

18:28

0 No events seen with RD53A, and few event correlations (<10 for MIMOSA 1 &2) between MIMOSA planes.
143

03/06/18

18:31

03/06/18

18:57

  

Before Run: Terminated and restarted EUDAQ Run Control.

Now seeing events with RD53A and more event correlations for MIMOSA. Only hitting diff FE; moving RD53A. Did not save root file.

144-145

03/06/18

18:58

03/06/18

19:48

  

Still moving RD53A.

Asked Control Room to change rate from [First Mode 5Hz] . Increased rate by opening the collimators. Decreased rate @ 19:49.

146

03/06/18

19:53