CSPAD alignment history
CXI DSD
...
- 2012-11-08 Run6 DSD CSPad alignment
Archive: /reg/g/psdm/detector/alignment/cspad/calib-cxi-dsd-2012-11-08/*/0-end.data
...
...
CXI DS1
- 2011-05-25 CSPad alignment parameters, see for detail CSPad alignment after run 3, cxi80410-r0628
Archive: /reg/g/psdm/detector/alignment/cspad/calib-cxi-ds1-2011-03-11/
Deployed: /reg/d/psdm/CXI/cxi80410/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/ - 2011-06-20 CSPad alignment parameters, see for detail CSPad alignment before run 4, cxi35711-r0009
Numerous attempts of quad alignment have been done with this optical measurements.
Archive: /reg/g/psdm/detector/alignment/cspad/calib-cxi-ds1-2011-06-20
Deployed: /reg/d/psdm/CXI/cxi35711/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/
cxi37411,cxi80410,cxi43312,cxi39112,cxi49812,cxi49012,cxii0212,cxi64813
- 2013-04-19 CSPad CxiDs1 alignmen
Archive: /reg/g/psdm/detector/alignment/cspad/calib-cxi-ds1-2013-04-19/*/0-end.data - 2013-12-20 CSPAD DS1 Alignment - new optical measurements for the refurbished DS1 camera
and 2014-03-05 alignment of quads using lysozyme image from cxi83714 run 136.
Archive: /reg/g/psdm/detector/alignment/cspad/calib-cxi-ds1-2013-12-20/
Deployed: /reg/d/psdm/cxi/cxib8914/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data
cxi83714, cxib6714, cxii0114 - 2014-03-19 CSPAD DS1 Alignment - refurbished DS1 camera, optically re-measured quads 1 and 3
and 2014-03-21 alignment of quads using bright ring from cxii0114 run 227.
Local: ~dubrovin/LCLS/CSPadAlignment-v01Archive: /reg/g/psdm/detector/alignment/cspad/calib-cxi-ds1-2014-03-19/*/0-end.data
Deployed: /reg/d/psdm/cxi/cxii0114/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/4-end.data
cxid8114
- 2014-05-15 CSPAD DS1 Alignment - refurbished DS1 camera, optically re-measured quad 2.
2014-06-05 alignment of quads using lysozyme image from cxid2714 run 23.
LocalArchive: /reg/nehg/home1psdm/dubrovindetector/LCLSalignment/CSPadAlignment-v01cspad/calib-cxi-ds1-2014-05-15/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data
Deployed: /reg/d/psdm/cxi/cxid6214/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data or 1-end.data
cxid9114, cxie1514, cxie1414, cxie2614, cxie2214, cxie3014, cxie3214, cxie4314, cxie3914, cxid6014, cxid5714, cxic4414, cxid2714, cxic8214
CXI DSD
- 2011-08-DD DSD CSPad alignment parameter, cxi37411, CxiDsd.0 - alignment is based on optical measurement only
Archive: /reg/g/psdm/detector/alignment/cspad/
Deployed: /reg/d/psdm/CXI/cxi37411/calib/CsPad::CalibV1/CxiDsd.0:Cspad.0/ - 2012-01-19 CSPad CxiDsd alignment for cxi80410-r1150, cxi43312, cxi39912, etc.
Archive: /reg/g/psdm/detector/alignment/cspad/calib-cxi-dsd-2012-01-10/
Deployed: /reg/d/psdm/CXI/cxi80410/calib/CsPad::CalibV1/CxiDsd.0:Cspad.0/
cxi43312,
should be copied to cxi39912 (are the Ds1 and Dsd detectors swaped ?)
- 2012-11-08 Run6 DSD CSPad alignment
Archive: /reg/g/psdm/detector/alignment/cspad/calib-cxi-dsd-2012-11-08/*/0-end.data
- 2013-12-12 CSPAD DSD Alignment - new optical measurements for the refurbished DSD camera
Archive: /reg/g/psdm/detector/alignment/cspad/calib-cxi-dsd-2013-12-12
Deployed: /reg/d/psdm/cxi/cxib8914/calib/CsPad::CalibV1/CxiDsd.0:Cspad.0/*/0-end.data
cxi83714, cxib6714, cxii0114
CXI DS2 (formed DSD)
- 2014-05-15 CSPAD DS2 Alignment - all quads remeasured, Z information is missing
LocalArchive: /reg/nehg/home1psdm/dubrovindetector/LCLSalignment/CSPadAlignment-v01cspad/calib-cxi-ds2-2014-05-15/calib/CsPad::CalibV1/CxiDs2.0:Cspad.0/*/0-end.data
Deployed: /reg/d/psdm/cxi/cxid9114/calib/CsPad::CalibV1/CxiDs2.0:Cspad.0/*/1-end.data
cxid6214, cxie1514, cxie1414, cxie2614, cxie2214, cxie3014, cxie3214, cxie4314, cxie3914, cxid6014, cxid5714, cxic4414, cxid2714(as dsd), cxic8214 - 2014-08-27 CSPAD DS2 Alignment - Z information is discarded discarded
LocalArchive: /reg/nehg/homepsdm/dubrovindetector/LCLSalignment/CSPadAlignment-v01cspad/calib-cxi-ds2-2014-08-27/calib/CsPad::CalibV1/CxiDs2.0:Cspad.0/*/0-end.data
CXI Camera1
...
(formed DS1)
- 2014-09-24 CSPAD Camera1 Alignment (formed DS1)
Archive:- /reg/g/psdm/detector/alignment/cspad/calib-cxi-camera1-2014-09-24/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/geometry/0-end.data
- /reg/g/psdm/detector/alignment/cspad/calib-cxi-camera1-2014-09-24/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/geometry/geometry-camera1-in-ds2-cxih8015-r176.data
CXI Camera2 (formed DS2)
- 2015-01-20 CSPAD Camera2 Alignment (formed DS2)
Archive:- /reg/g/psdm/detector/alignment/cspad/calib-cxi-camera2-2015-01-20/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/geometry/*.data
- /reg/g/psdm/detector/alignment/cspad/calib-cxi-camera2-2015-01-20/calib/CsPad::CalibV1/CxiDs2.0:Cspad.0/geometry/*.data
...
- 2016-02-05 CSPAD Camera2 Alignment
Archive: /reg/g/psdm/detector/alignment/cspad/calib-cxi-camera2-2016-02-05/calib/CsPad::CalibV1/CxiDs2.0:Cspad.0/geometry/1-end.data
XPP/XCS
- 2011-08-10 XPP CSPAD alignment parameters, see for detail CSPad alignment for xpp36211-r0544
DeployedArchive: /reg/dg/psdm/XPPdetector/alignment/xpp36211cspad/calib/CsPad::CalibV1/XppGon.0:Cspad.0/2012-01-DD XppGon.0:Cspad.0 alignment - copy of the xpp36211 parameters.-xpp-2011-08-10
Deployed: /reg/d/psdm/XPP/xpp47712xpp36211/calib/CsPad::CalibV1/XppGon.0:Cspad.0/,
xpp47712
- 2012-02-26 CSPad XppGon alignment for xppcom10 etc.
Local: ~dubrovin/LCLS/CSPadAlignment-v01Archive: /reg/g/psdm/detector/alignment/cspad/calib-xpp-2012-02-26/*/0-end.data
copied to: ~dubrovin/LCLS/CSPadAlignment-v01/calib-xppcom10-r1437-XppGon/*/1423-end.data
Deployed: /reg/d/psdm/XPP/xppcom10/calib/CsPad::CalibV1/XppGon.0:Cspad.0/*/1423-end.data
- 2013-01-24 CSPad XPP alignment
Archive: /reg/g/psdm/detector/alignment/cspad/calib-xpp-2013-01-24/calib/CsPad::CalibV1/XppGon.0:Cspad.0/*/0-end.data
Deployed: /reg/d/psdm/XPP/xppcom13/calib/CsPad::CalibV1/XppGon.0:Cspad.0/*/0-end.data
...
- 2013-12-10 Qaud MEC Alignment
Archive: /reg/g/psdm/detector/alignment/cspad/calib-mec-2013-12-10/
Deployed: /reg/d/psdm/mec/meca1113/calib/CsPad::CalibV1/MecTargetChamber.0:Cspad.0/*/0-end.data
Archive with corrected z coordinates: /reg/g/psdm/detector/alignment/cspad/calib-mec-2013-12-10-improved-Z/ - 2013-12-20 Qaud MEC Alignment - new optical measurements after quad repair
Deployed: /reg/d/psdm/MEC/meci0114/calib/CsPad::CalibV1/MecTargetChamber.0:Cspad.0/*/0-end.data
Archive: /reg/g/psdm/detector/alignment/cspad/calib-mec-2013-12-20/calib/ - 2015-04-03 Quad1 MEC Alignment
Archive: /reg/g/psdm/detector/alignment/cspad/calib-mec-2015-04-03/calib/CsPad::CalibV1/MecTargetChamber.0:Cspad.0/geometry/1-end.data - corrected, 0-end.data is non-corrected - 2015-06-08 Quad1 MEC Alignment
Archive: /reg/g/psdm/detector/alignment/cspad/calib-mec-2015-06-08/calib/CsPad::CalibV1/MecTargetChamber.0:Cspad.0/geometry/0-end.data MEC camera got two other quads (quad 1 and 2), but there is no optical measurements for them.
Known detectors
on 2014-07-04:
...