Page History
...
- Optical Metrology file:
- 2014-09-24-CXI-Camera1-Metrology.xlsx
- <https://confluence.slac.stanford.edu/download/attachments/107749188/2014-09-24-CXI-DS1-Metrology.xlsx?version=1&modificationDate=1414457576000&api=v2>
- 2014-09-24 -- fixed and moved to DS2 chamber
- mixed quadrants:
- 3 old A boards (Q0, Q1, Q2), 4/40
- 1 new board (Q3), 3/19
- mixed quadrants:
- 2014-11-19 -- DS1 @ DSD
- moved back to DS1 chamber in DSD location
- Used for PCS, IH and cxig3616
- 2015-01-10 -- DS1 @ DSC location
- Used for cxig1515
- src = 'DetInfo(CxiDs1.0:Cspad.0)'
- alias = DscCsPad
- Relative detector Z position:
- alias = 'DscCsPad_z'
- pv = 'CXI:DS1:MMS:06.RBV'
- Used for cxig1515
- 2015-03-17 -- DS2 @ DSD location
- Camera 1 was moved to DS2 chamber at DSD location.
- The previously broken D50 Concentrator was replaced with older concentrator.
- Quadrants 2 and 0 were swapped.
- Back detector (generally not used) for SC1 experiments from 2015-03-18 to 2015-05-04
- src = 'DetInfo(CxiDs2.0:Cspad.0)'
- alias = DsdCsPad
- Relative detector Z position:
- alias = 'DsdCsPad_z'
- pv = 'CXI:DS2:MMS:06.RBV'
- Camera 1 was moved to DS2 chamber at DSD location.
- 2015-05-04 -- DS2 @ DSD
- Cables for Camera 1 in DS2 corrected and collimator pipe removed from front DS1
- Back detector for SC1 experiments from 2015-05-04 to 2015-05-17
- src = 'DetInfo(CxiDs2.0:Cspad.0)'
- alias = DsdCsPad
- Relative detector Z position:
- alias = 'DsdCsPad_z'
- pv = 'CXI:DS2:MMS:06.RBV'
- 2015-12-07 -- DS1 @ DSC
- Camera1 was moved from DS2 (at DSD) to DS1 (at DSC) because Camera2 in DS1 was damaged.
- src = 'DetInfo(CxiDs1.0:Cspad.0)'
- alias = DscCsPad
- Relative detector Z position:
- alias = 'DscCsPad_z'
- pv = 'CXI:DS1:MMS:06.RBV'
- Camera1 was moved from DS2 (at DSD) to DS1 (at DSC) because Camera2 in DS1 was damaged.
Camera2_V16_20150120
- 2015-02-02 -- DS2 chamber with refurbished Camera2 moved to DSA location
- Non-standard configuration given D50 CsPad rack concentrator, which is normally used with DS2 chamber, was broken.
- Used D51 CsPad rack for concentrator and motors Februatry 2015 experiments in the SC2 (a.k.a. SC01, 100nm focus chamber).
- cxig0715, cxie7015, cxie7515 and cxif5315
- src = 'DetInfo(CxiDs2.0:Cspad.0)'
- alias = DsaCsPad
- Relative detector Z position:
- alias = 'DsaCsPad_z'
- pv = 'CXI:DS1:MMS:06.RBV'
- Similarly, other relevant epicsStore aliases begin with DsaCsPad.
- The mapping of the D50 concentrator is rotated by 90 relative to the D51 concentrator.
- 2015-03-03 -- Moved DS2 chamber with Camera2 to DSD location
- Used for SPI experiment cxi86415
- src = 'DetInfo(CxiDs2.0:Cspad.0)'
- alias = DsdCsPad
- Relative detector Z position:
- alias = 'DsdCsPad_z'
- pv = 'CXI:DS2:MMS:06.RBV'
- Note pipe in front DS1 chamber detector during this experiment was removed, but the holder for it was still in providing circular aperture for back DS2 detector
- Used for SPI experiment cxi86415
- 2015-03-17 -- Added shield and pipe and moved Camera2 to DS1 chamber
Used for SC1 experiments starting at the end of Run10:
- cxig0915, cxii6315, cxih0115, cxih0815, April PCS, cxih9515, cxii2415, ...
- src = 'DetInfo(CxiDs1.0:Cspad.0)'
- alias = DscCsPad
- Relative detector Z position:
- alias = 'DscCsPad_z'
- pv = 'CXI:DS1:MMS:06.RBV'
- Detector Attenuation from shields and coatings (pipe and additional shielding required for laser experiments):
- CsPad Pipe Al Shield Transmission:
8 um thick polyimide
1 um thick Al on upstream side
1.75 um thick Al on downstream side
The detectors have 0.25 um thick Al coating.
--> 3 um total Al
- CsPad Pipe Al Shield Transmission:
- 2015-05-04 -- Removed shield and pipe from Camera2 in DS1 chamber
Used for SC1 experiments starting with cxih8015:
- src = 'DetInfo(CxiDs1.0:Cspad.0)'
- alias = DscCsPad
- Relative detector Z position:
- alias = 'DscCsPad_z'
- pv = 'CXI:DS1:MMS:06.RBV'
...