Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Camera2_V16_20150120

  • 2015-02-02 -- DS2 chamber with refurbished Camera2 moved to DSA location
    • Non-standard configuration given D50 CsPad rack concentrator, which is normally used with DS2 chamber, was broken.
    • Used D51 CsPad rack for concentrator and motors Februatry 2015 experiments in the SC2 (a.k.a. SC01, 100nm focus chamber). 
      • cxig0715, cxie7015, cxie7515 and cxif5315
      • src = 'DetInfo(CxiDs2.0:Cspad.0)'
      • alias = DsaCsPad
      • Relative detector Z position:  
        • alias = 'DsaCsPad_z' 
        • pv = 'CXI:DS1:MMS:06.RBV'
      • Similarly, other relevant epicsStore aliases begin with DsaCsPad.
    • The mapping of the D50 concentrator is rotated by 90 relative to the D51 concentrator.
  • 2015-03-03 -- Moved DS2 chamber with Camera2 to DSD location
    • Used for SPI experiment cxi86415
      • src = 'DetInfo(CxiDs2.0:Cspad.0)'
      • alias = DsdCsPad
      • Relative detector Z position:  
        • alias = 'DsdCsPad_z' 
        • pv = 'CXI:DS2:MMS:06.RBV'
    • Note pipe in front DS1 chamber detector during this experiment was removed, but the holder for it was still in providing circular aperture for back DS2 detector
  • 2015-03-17 -- Added shield and pipe and moved Camera2 to DS1 chamber
    • Used for SC1 experiments starting at the end of Run10:

      • cxig0915, cxii6315, cxih0115, cxih0815, April PCS, cxih9515, cxii2415, ...
      • src = 'DetInfo(CxiDs1.0:Cspad.0)'
      • alias = DscCsPad
      • Relative detector Z position:  
        • alias = 'DscCsPad_z' 
        • pv = 'CXI:DS1:MMS:06.RBV'
    • Detector Attenuation from shields and coatings (pipe and additional shielding required for laser experiments):
      • CsPad Pipe Al Shield Transmission:
        • 8 um thick polyimide 

        • 1 um thick Al on upstream side

        • 1.75 um thick Al on downstream side

      • The detectors have 0.25 um thick Al coating.

      • --> 3 um total Al

  • 2015-05-04 -- Removed shield and pipe from Camera2 in DS1 chamber
    • Used for SC1 experiments starting with cxih8015:

      • src = 'DetInfo(CxiDs1.0:Cspad.0)'
      • alias = DscCsPad
      • Relative detector Z position:  
        • alias = 'DscCsPad_z' 
        • pv = 'CXI:DS1:MMS:06.RBV'
DateWhoGeometry File NameFile Type

Comment

2015-06-27valerio

/reg/g/psdm/detector/alignment/cspad/openGeom/crystfel/

2015-06-27-cxih9615.geom

cxidbThe refined geometry file for LH96 (Obertheuer beamtime)
2015-04-01

valerio

/reg/g/psdm/detector/alignment/cspad/openGeom/crystfel/

2015-04-01-cxii6315-ds1.geom

cxidb

The refined geometry file for LI63 (Zatsepin beamtime)

Mislabeled in openGeom folder

2015-03-21valerio

/reg/g/psdm/detector/alignment/cspad/openGeom/crystfel/

2015-03-21-cxig0915-ds1.geom

cxidb

The final refined geometry file for LG09 (Schmidt beamtime) for CXIDB data format.

Mislabeled in openGeom folder

2015-03-26cpo

/reg/g/psdm/detector/alignment/cspad/calib-cxi-camera2-2015-01-20/calib/CsPad::CalibV1/CxiDs2.0:Cspad.0/geometry/0-end.data 

psanaGenerated from 2015-01-20-CSPAD-CXI-Camera2-Metrology.xlsx
2015-03-25

blaj

dubrovin

2015-01-20-CSPAD-CXI-Camera2-Metrology.xlsx

/reg/g/psdm/detector/alignment/cspad/calib-cxi-camera2-2015-01-20/2015-01-20-CSPAD-CXI-Camera2-Metrology.txt

xlsx

txt

optical metrology

converted using calibman

...