Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Camera1_V16_20140924

DateWhoGeometry File NameFile Type

Comment

2015-04-01valerio

/reg/g/psdm/detector/alignment/cspad/CXI_Camera1/crystfel/

2015-04-01-cxii6315-ds1.geom

cxidbThe refined geometry file for LI63 (Zatsepin beamtime)
2015-03-21valerio

/reg/g/psdm/detector/alignment/cspad/CXI_Camera1/crystfel/

2015-03-21-cxig0915-ds1.geom

cxidbThe final refined geometry file for LG09 (Schmidt beamtime) for CXIDB data format.
2015-03-26cpo

/reg/g/psdm/detector/alignment/cspad/calib-cxi-ds1-2014-09-24/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/geometry/0-end.data

psanaGenerated from 2014-09-24-CSPAD-CXI-DS1-Metrology.xlsx
2015-03-25

blaj

dubrovin

2014-09-24-CSPAD-CXI-DS1-Metrology.xlsx

/reg/g/psdm/detector/alignment/cspad/calib-cxi-ds1-2014-09-24/2014-09-24-CSPAD-CXI-DS1-Metrology.txt

xlsx

txt

optical metrology

converted using calibman

Camera2_V16_20150120

  • 2015-02-02 -- DS2 chamber with refurbished Camera2 moved to DSA location
    • D50 CsPad rack concentrator was broken.
    • Used D51 CsPad rack for concentrator and motors Februatry 2015 experiments in the SC2 (a.k.a. SC01, 100nm focus chamber). 
      • cxig0715, cxie7015, cxie7515 and cxif5315
      • src = 'DetInfo(CxiDs2.0:Cspad.0)'
      • alias = DsaCsPad
      • relevant epicsStore aliases begin with DsaCsPad:
        • Relative detector Z position:  
          • alias = 'DsaCsPad_z' 
          • pv = 'CXI:DS1:MMS:06.RBV'

  • 2015-03-17 added shield and pipe and moved Camera2 to DS1 chamber
    • CsPad Pipe Al Shield Transmission:

      • 8 um thick polyimide 

      • 1 um thick Al on upstream side

      • 1.75 um thick Al on downstream side

    • The detectors have 0.25 um thick Al coating.

      • --> 3 um total Al

DateWhoGeometry File NameFile Type

Comment

2015-03-26cpo

/reg/g/psdm/detector/alignment/cspad/calib-cxi-ds2-2015-01-20/calib/CsPad::CalibV1/CxiDs2.0:Cspad.0/geometry/0-end.data 

psanaGenerated from 2015-01-20-CSPAD-CXI-DS2-Metrology.xlsx
2015-03-25

blaj

dubrovin

2015-01-20-CSPAD-CXI-DS2-Metrology.xlsx

/reg/g/psdm/detector/alignment/cspad/calib-cxi-ds2-2015-01-20/2015-01-20-CSPAD-CXI-DS2-Metrology.txt

xlsx

txt

optical metrology

converted using calibman

Camera2_V16_20140827

  • Quad 1 (zero based counting) reworked; metrology updated 
  • The other 3 quads (Q0, Q2, Q3) are unchanged (as in the previous metrology: May 14, 2014).
DateWhoGeometry File NameFile Type

Comment

2015-03-26cpo

/reg/g/psdm/detector/alignment/cspad/calib-cxi-ds2-2015-01-20/calib/CsPad::CalibV1/CxiDs2.0:Cspad.0/geometry/0-end.data 

psanaGenerated from 2015-01-20-CSPAD-CXI-DS2-Metrology.xlsx
2015-03-25

blaj

dubrovin

2015-01-20-CSPAD-CXI-DS2-Metrology.xlsx

/reg/g/psdm/detector/alignment/cspad/calib-cxi-ds2-2015-01-20/2015-01-20-CSPAD-CXI-DS2-Metrology.txt

xlsx

txt

optical metrology

converted using calibman

Camera3_V16_20131009

  • Out of vacuum camera typically used in XPP and XCS.
  • Used in CXI at DG4 location in December 2014.
DateWhoGeometry File NameFile Type

Comment

     
     

 

 

References

Documentation on data formats

...