Alignment procedure and parameters

Description of the detector geometry and alignment procedure can be found in
CSPAD Geometry and Alignment.

CSPAD alignment history

...

  • 2013-12-12 CSPAD DSD Alignment - new optical measurements for the refurbished DSD camera
    Local: ~dubrovin/LCLS/CSPadAlignment-v01/calib-cxi-dsd-2013-12-12/*/0-end.data
    (tick) Deployed: /reg/d/psdm/cxi/cxib8914/calib/CsPad::CalibV1/CxiDsd.0:Cspad.0/*/0-end.data
    (tick) Deployed: /reg/d/psdm/cxi/cxi83714/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data
    (tick) Deployed: /reg/d/psdm/cxi/cxib6714/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data
    (tick) Deployed: /reg/d/psdm/cxi/cxii0114/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data

  • 2013-12-20 CSPAD DS1 Alignment - new optical measurements for the refurbished DS1 camera
    and 2014-03-05 alignment of quads using lisozime image from cxi83714 run 136.
    Local: ~dubrovin/LCLS/CSPadAlignment-v01/calib-cxi-ds1-2013-12-20/*/0-end.data
    (tick) Deployed: /reg/d/psdm/cxi/cxib8914/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data(tick) Deployed: /reg/d/psdm/cxi/cxi83714/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data
    (tick) Deployed: /reg/d/psdm/cxi/cxib6714/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data
    (tick) Deployed: /reg/d/psdm/cxi/cxii0114/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/0-end.data

  • 2014-03-19 CSPAD DS1 Alignment - refurbished DS1 camera, optically re-measured quads 1 and 3
    and 2014-03-21 alignment of quads using bright ring from cxii0114 run 227.
    Local: ~dubrovin/LCLS/CSPadAlignment-v01/calib-cxi-ds1-2014-03-19/*/0-end.data
    (tick) Deployed: /reg/d/psdm/cxi/cxii0114/calib/CsPad::CalibV1/CxiDs1.0:Cspad.0/*/4-end.data

Known detectors

on 2013-12-17:

Code Block
           CxiDs1.0:Cspad.0
           CxiDsd.0:Cspad.0
           MecTargetChamber.0:Cspad.0
           XcsEndstation.0:Cspad.0
           XppGon.0:Cspad.0

 

Deployment of alignment parameters

CxiDs1

Code Block
Metrology    Experiments
2011-06-20   cxi35711 
             cxi37411 
             cxi80410 
             cxi43312 
             cxi39112 
             cxi49812 
             cxi49012 
             cxii0212
             cxi64813

...

Code Block
Metrology    Experiments
2011-08-10   xpp36211
2012-02-26   xppcom10
2013-01-24   xppcom13 - had problems with electronics. Is fixed on 2013-01-29:
2013-01-29   xppcom13 (when tested, should be copied for xppi0113, xppi0213, xppi0313, xpp66213, xpp66613, xpp67713) 
             xcs72913 - detector borrowed from xpp

References

CSPad metrology and calibration files, links - maintained by Philip Hart
CSPad detector - maintained by Philip Hart
CSPad2x2 Alignment 
CSPAD Geometry Software - Old - explains how the alignment parameters are used for reconstruction of the CSPad image in PSANA.
CSPad image producer in Python