Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • center - x, y, z center position of each 2x1 for all quadrants. Comes from optical measurement.
  • center_corr - additional manual correction to the center parameter. Can be applied if the optical measurement has (non-)obvious problems.
  • marg_gap_shift - margins, gaps, and shifts between quads, as explained below.
  • offset - x, y, z coordinates for 4 quads.
  • offset_corr - additional correction to the offset. Comes from image-based tuning.
  • quad_rotation - 4 quad rotation in n*90 degree. Comes from basic geometry.
  • quad_tilt - 4 quad tilt in fractional degree (has . Has never been used). In latest optical measurement is accounted through the global 2x1 coordinate measurement in the detector.
  • rotation - 8 2x1-rotation angle for 4 quads in n*90 degree. Comes from basic geometry.
  • tilt- 8 2x1-tilt angle for 4 quads in fractional degree. Comes from optical measurement.

offset_corr

For individual quad position alignment use file: offset_corr/<run-range>.data

...