Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The Ecal temperatures should be around 70F.

SVT Voltages brings up:

Turning power ON

Make sure that the box to the right of the OFF/ON buttons are RED.

...

One special feature is that the DVDD power is coupled between two hybrids (0&1,2&3, and so on). This means that powering down always results in powering down BOTH hybrids. This is expected and normal behavior.

Turning on BIAS voltage for all modules on the SVT

Never do this without explicit instructions from an expert!

Find the GUI for the SVT voltages.

There is a box in the upper right corner "Bias Voltage Setpoints". Input your new bias voltage value and hit Enter. This will propagate this voltage to all SVT modulels.

To turn bias on individually please look at the section below.

What to look for:

Alarm panel

...

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="9722cdb3bfb1a0a9-2f49bc03-493b4ba5-a109b918-b8d96ac4a32c2b811de2b1a8"><ac:plain-text-body><![CDATA[

 

Low [mA]

High [mA]

]]></ac:plain-text-body></ac:structured-macro>

DVDD

230

260

AVDD

380

420

V125

260

320

...