<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="60a8adee8f068378-49c84225-4ed34551-b439a3d1-2ece05435b76eb4658b6e1e9"><ac:plain-text-body><![CDATA[

 

Low [mA]

High [mA]

]]></ac:plain-text-body></ac:structured-macro>

DVDD

230

260

AVDD

380

420

V125

260

320

...

High voltage bias for the SVT

...

When

High voltage should be at 180V during normal operations/data taking.al range of values for low voltage currents and

Changing high voltage bias during normal operation (data taking) is shown in the tables below.

<ac:structured-macro ac:name="unmigrated-wiki-markup" ac:schema-version="1" ac:macro-id="9cf9927c-43f0-45c0-9c06-1c0b07b090b6"><ac:plain-text-body><![CDATA[

 

Low [mA]

High [mA]

]]></ac:plain-text-body></ac:structured-macro>

DVDD

230

260

AVDD

380

420

V125

260

320

...

values is an expert only action

Changing voltages

Wiki Markup
In EPICS control gui we can click the button to the right saying "Hybrid x" (x=\[0,9\]) and a new GUI pops up showing more options.

...