Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0

...

* Allow an arbitrary number of fitting algorithms.
* Provide fit data per plane, per wire, for all fitting algorithms (but careful because some algorithms don't give the parameters of others, so it isn't straight forward to templatize (eg not all have chiSq).
* Provide rms, mean, area for each wire, all planes
* Return a beam centered flag?(centroid positions wrt scan range)
* Store fit data, along with raw data with "Store Scan" button, labeled and timestamped.
* Load fit data and raw data upon "Load Scan" and after choosing appropriate labeled and timestamped item.
* Always update the last good scan fit and raw data for this wire, this plane (if good).

8  Plotting

Wiki Markup\* Plot last good scan in respective plane until new scan is completed \* All plots need to be labeled and timestamped \* Plot current  scan in respective plane after completed by IOC and data is read from IOC \* Allow labeling by motor position or * Plot last good scan in respective plane until new scan is completed
* All plots need to be labeled and timestamped
* Plot current  scan in respective plane after completed by IOC and data is read from IOC
* Allow labeling by motor position or x,y,u coordinates (Phase 2). \* Pick scan inner and outer values by clicking on data plot, after selecting respective "Pick" button \* Raw data
* Pick scan inner and outer values by clicking on data plot, after selecting respective "Pick" button
* Raw data (2-D) Plot -   o color coded by device   o "show selected" devices only option \* Profile data -
  o color coded by device
  o "show selected" devices only option
* Profile data (2-D) Plot - Wire position (um, x axis) versus PMT signal (QDCRAW, y axis)   o connect adjacent points with dashed lines   o selected fit is superimposed, different color   o plot redraws when changing fit selection   o numeric fit data displayed: \
  o connect adjacent points with dashed lines
  o selected fit is superimposed, different color
  o plot redraws when changing fit selection
  o numeric fit data displayed: [x,y,u\]area (Mcts), \ [x,y,u\]mean (mm), \ [x,y,u\]rms (um) \* Dispersion Plot for WS04 \- using dispersion at wire from model, compute energy axis in Profile Plot \* Display design rms, design
* Dispersion Plot for WS04 - using dispersion at wire from model, compute energy axis in Profile Plot
* Display design rms, design emittance

9  External Interfaces

* CMLOG logging
* On-line model
* Shares fitting algorithms / plotting with other apps
* Wire Scan public API - Allow other applications - Emittance, Correlation Plots, etc, to:
  o Control wire scans 
  o Retrieve raw data and fit data
  o Retrieve Data Plots - profile, raw