Final focus and dump spectrometer quad BBA.
LGPS | Nearest BPM | XOFF (EPICS) | XOFF (SCP) | YOFF (EPICS) | YOFF (SCP) | Date | Implemented? | Link to data |
---|---|---|---|---|---|---|---|---|
3011 (Q5FF) | LI20:BPMS:3013 | 0 | +0.65 | 11/10/2022 | 11/11/2022 | http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2022/45/10.11&pos=2022-11-10T16:04:57 | ||
3311 (Q4FF) | LI20:BPMS:3036 | 0.4216 | -0.14 | 11/10/2022 | 11/11/2022 | http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2022/45/10.11&pos=2022-11-10T16:42:34 | ||
3151 (Q3FF) | LI20:BPMS:3036 | 0.4216 | -0.14 |
2/ |
20/ |
2024 | 11/11/2022 | http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2024/08/20.02&pos=2024-02-20T15:01:36 http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2024/08/20.02&pos=2024-02-20T15:15:39 | ||||
1910 (Q2FF) | LI20:BPMS:3101 | 0.3519 | 0.3166 | 2 |
/20/2024 | http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2024/08/20.02&pos=2024-02-20T15:44:32 http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2024/08/20.02&pos=2024-02-20T17:01:19 | |||||||
3204 (Q1FF) | LI20:BPMS:3120 | 0.1437 | -0.5386 | 2/15/2015 | ||||
3031 (Q0FF) | BPMS:LI20:3156 | 0 | -0.5533 | 0.16 - 0.1 | 0 | 11/11/2022 | http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2022/45/11.11&pos=2022-11-11T13:26:56 http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2022/45/11.11&pos=2022-11-11T13:39:07 | |
LI20:BPMS:3167 | 0 | 0 | ||||||
LI20:BPMS:3187 | 0 | 0 | ||||||
3141 (Q0D) | BPMS:LI20:3218 | 0 +0.2 | 0 -0.25 | 12/06/2022 | ||||
3261 (Q1D) | BPMS:LI20:3265 | -0.6 + 0.2 | 0.5199 † | -0.14 † | 0 | 12/06/2022 | ||
3091 (Q2D) | BPMS:LI20:3315 | 0.51 - 0.5 | -0.9339 † | -0.21 + 1.5 † | -0.475 | |||
LI20:BPMS:3340 | -4.64 | 6.349 |
Notes:
- Q2D measurements attempted by using PRDMP screen as measurement with some success in y-plane. Transverse jitter at time of measurements spoiled x-plane.
- † The 3265 and 3315 BPMS have had persistent NOQ calibration errors which no amount of troubleshooting or investigation have seemingly provided insight into resolving. They are multiplexed in EPICS so the EPICS measurements should be used.