Webex Connection Details - Briefing Meeting Oct.9-2013

Webex Connection Details - Ecal Review Oct.17, 2013

Review Charge

List of Questions from M.Garcon

List of Questions from J.Jaros

List of Questions with Answers (Summary Table)

...

Link to the CLAS12 Forward Tagger TDR

http://www.ge.infn.it/~batta/jlab/ft-tdr.2.0.pdf

...

coupled to PMT and a 10x10 APD at pg 27

Agenda

Time (Pacific)

Title & Speaker

Duration

Post your talk here

7:00 am

Project Organization & Overview, R. Dupré (IPNO)

10'

Overview.pdf

7:10 am

Motherboards, M. Battaglieri (INFN)

15'

Slides Pratolongo MB

7:25 am

Pre-amplifiers, E. Rauly (IPNO)

15'

HPS_17oct2013_rauly_v3.pdf

7:40 am

Light Monitoring System, A. Celentano (INFN)

20'

Celentano-LedMonitor.pdf

8:00 am

Mechanics and Thermal System, P.Rosier (IPNO)

20'

mechanics_integration.pdf

8:20 am

New APDs installation, M. Battaglieri (INFN)

30'

APD replacement Battaglieri

8:50 am

Commissioning, Calibration and Interfaces F. X. Girod (JLab)

15'

girod_HPS_ecal_review.pdf

9:05

Schedule, Budget & Conclusions, R. Dupré (IPNO)

20'

SBC-HPS.pdf

 

 

 

 

9:30 am

Closed Session (Review Panel only)

60' 

Final Report 10/29/2013

Material for the Review

Pre-amps calibration (E.Rauly)

Thermal Enclosure (P.Rosier)

Link to the CLAS12 Forward Tagger TDR http://www.ge.infn.it/~batta/jlab/ft-tdr.2.0.pdf. You will find results of LY measurement with BCTP PbWO-II crystals coupled to PMT and a 10x10 APD at pg 27.

Light Yeld estimate for a ECal crystal (old BTCP PbWO) from the HPS proposal  pag. 157, top-left panel . These are the measurements we performed in Genova, with a HPS-like crystal (from CLAS-IC),  a LA-APD, and a FT-Cal amplifier. The mean energy deposited in the crystal by cosmics is ~ 15 MeV. The corresponding mean charge collected is ~ 25 pC.The amplifier and APD gain were, respectively, 1800 and 150.  Measure was performed at 18 +++ 1 deg. This gives an average LY of : 25 / (1800 * 150 * 1.6E-7 *15) ~ 35 phe / MeV

"PbWO4 light output" email thread

O.Pogorelko's presentation where he takes 12 p.e./MeV and multiplies by 3 for "our crystals" and comes up with with "3.6 p.e./MeV at APD".  If we assume that 3.6 does not include QA=0.75 of APD, than real p.e./MeV will be 2.7. To many inconsistency. I think we should rely on what we (Andrea) measured.

HPS Proposal May'13

DOE Review July 11, 2011
 

Review Panel 

 

 

 

Marco Oriunno

SLAC

Chair

John Jaros

SLAC

Co-Chair

Stepan Stepanian

JLAB

Co-Chair

Raphael Dupre

IPNO Orsay

Link person to the ECAL project

Michel Garcon

CEA-Saclay

External Reviewer

Elton Smith

JLAB

External Reviewer