We should try to break this when we can.

6:40pm

The hybrid power monitoring and control now works through the hybrid GUI. It's mapped using feb index. Getting the physical name for it on the GUI is a little tricky but I'm working on it so until then you need to find out which feb nr you have powered (either from the non-zero hybrid currents that are updating, the temperature GUI or the daq GUIs). 

1/30/15

10:00AM - PH
Testing L4b (serial #15) mounted on production plate placed on the test bench. Using one of the spare flanges that are not potted.The FEB ID is 2, data "DPM:channel" is 0:0, 0:1, 0:2 and 1:0. I see a few data link errors on 0:2. All hybrids sync. Took ~5000 events, file name is test.dat_000785.evio.0.

10:30AM - PH
Testing L1t (serial #01) with same setup as the L4b above. All hybrids sync. Took ~6400 events, file name is test.dat_000787.evio.0.

11:50AM - PH

There is a broken pin on L1t (serial #01). That particular one is not used. Retesting with same setup as the L4b above.  All hybrids sync. Took ~4800 events, file name is test.dat_000789.evio.0.

Equipment

Interlock board

see Group C interlock board for instructions on monitoring and controls.

...