I don't think the other variables will change very much, if at all.
Zero Suppression threshold. (Oct 10, Julie)
The code/parameters used to correct for the effect of the zero suppression threshold in the cal
in CalValsTool is tuned for a threshold of 1 MeV. The value used in the simulation is 2 MeV, so there
is a mismatch, between the simulation and reconstruction. This results in an underestimate of the
reconstructed energy (particularly for low energy events).