Detector Number | Type | Function | In DAQ? | Notes | Cabled? | Running? | Comments |
---|---|---|---|---|---|---|---|
1 | ePix100a | XRTS | Yes | in-vac | NW flange | Yes | ePix 0 |
2 | ePix100a | XTCS | Yes | in-vac | Yes | Yes | ePix 1 |
4 | opal 2K | e- spectrometer | Yes | in-air | Yes | Yes | opal4_electron_spectrometer EDT boxes green, but standalone EDT code on daq-mec-cam03 doesn't read camera ID. DAQ control error. |
5 | opal 4K | Thomson Parabola | Yes | in-air | Yes | Yes | opal3_thomson_parabola |
6 | opal 2K | NF/FF | Yes | in-air | Yes | Yes | opal1_nf_ff Replaced 1K with 2K. |
7 | opal 4K | Imaging spot | Yes | in-air | Yes | Yes | opal2_focus_img |
8 | opal 4K | Time Tool | Yes | in-air | Yes | Yes | |
9 | Zyla | MXI | Yes | in-air | Yes | Yes | zyla_xray_east |
10 | gigE POE | replacement for GIGE4 | No | in-air, using old GIGE-MEC-CAM08 (Mako G-032B POE) | Yes | Yes | Now known as the beamline camera "XRay_Imaging" |
11 | gigE POE | SPL_TC_alignment | No | in-air, using old GIGE-MEC-CAM07 (Mako G-032B POE) | Yes | Yes | It does run well. From time to time, it 'freezes' such that we have to start/stop again. Nothing serious. The camera works well for its purpose! |
| |||||||
13 |
| ||||||
|