Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0

Reason for change

The new version contains some fine tuning of specific limits, as well as the new alarms on the normalized rates; the proposed version of the dataMonitoring/AlarmsCfg package is v5r8p8, as opposed to v5r8p4(v5r9p0, as opposed to v5r8p8, previously running in L1Proc 1.70) include a very minor change, namely two more exceptions to the calorimeter pedestal alarms.
The detailed description of the changes is in the last section.

...

The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.

CCB Jira

SSC-170@JIRA173@JIRA

Details

...

v5r9p0

  • Added a couple more exception on CAL ped rms values, channel 848.