Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Code Block
======================================= Ignore Logic ===========================================

------------------------------------------------------------------------------------------------
                                          Logic History

 |=========================< slider >============================================|  [] Show Live

------------------------------------------------------------------------------------------------
         Ignore Logic                                      Ignored Truth Tables
   Sort 2        Sort 0      Sort 1   |                Sort 1                    Sort 0
============== ===========  ========  |   ================================ =================
  Condition    Is Ignoring  Min Rate  |   Truth Table                           Min Rate
============== ===========  ========  |   ================================ =================
TD11 Is In         Yes         0 Hz   |   BFW 1910 Position                             0 Hz
TDUND Is In         No        10 Hz   |   BCS LION753 Threshold                         0 Hz
YG BL211 Is In      No        60 Hz   |   BLM Pedestal Thresholds: UND 920              0 Hz
============== ===========  ========  |   Temperature: North Arc Summary                0 Hz
                                      |   VVPG LI22 Position                            0 Hz
                                      |   YAG IN20 211 Position                        10 Hz
                                      |   PIC HVPS B912                                10 Hz
                                      |   PIC HVPS B913                               120 Hz
                                      |   ================================ =================
                                      |
--------------------------------------+------------------------------------------------------

         Name: YAG IN20 211 Position
 Ignored When: TD11 Is In, or YG BL211 Is In, or ...
Current State: Out
     Solution: --
     Contacts: --

====== = = ==================== ==================== ==================== ====================
 Name  B A     Pockels Cell      Mechanical Shutter         BYKIK         Laser Heater Shutter
====== = = ==================== ==================== ==================== ====================
Moving F F                 0 Hz                 0 Hz                 0 Hz                   --  [Bypass to this state]
Out    F T               120 Hz               120 Hz               120 Hz                   --  [Bypass to this state] -> window shows PVs and asks for bypass time
In     T F                10 Hz                10 Hz                10 Hz                   --  [Bypass to this state]
Broken T T                 0 Hz                 0 Hz                 0 Hz                   --  [Bypass to this state]
====== = = ==================== ==================== ==================== ====================

Where::

    = ======================================= ========= ========= ========== ==========
    . PV Prefix                                Current   Latched  Bypass Act Bypass Val
    = ======================================= ========= ========= ========== ==========
    A (YG_BL211_OUT_LIMIT)_(STATE) as PV Name IS_OUT    IS_OUT        No     IS_NOT_OUT
    B (YG_BL211_IN_LIMIT)_(STATE) as PV Name  IS_NOT_IN IS_NOT_IN     No     IS_NOT_IN
    = ======================================= ========= ========= ========== ==========

Note to sergei:  (Device Name)_(Fault Name) from config db



------------------------------------------------------------------------------------------------
Summary / Faults / Logic / Ignore Logic / History /


Note to sergei:  Use (Device Name)_(Fault Name) to find PV prefix from config db

Ignore Logic Mockup

Test on lcls-dev2

...