Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Switch

IOCs for Feedback

swh-in20-nw02

in20-bp01, in20-bp02, in20-rf01

swh-li21-nw01(question) 

li21-bp01, li21-bp02, li21-bl01**

swh-li24-nw01     

li24-bp01, li24-bp02, li24-rf01, li24-bl01

swh-b136-nw01

bsy0-bp01

swh-b106-nw01

bsy0-bp02

swh-b105-nw01

ltu0-bp01, ltu1-bp01, ltu0-mg01?

 swh-b911-nw01

ltu1-bp02, ltu1-mg01?

swh-b912-nw01

ltu1-bp03, ltu1-mg02?

swh-b913-nw01

ltu1-bp04, und1-bp01, und1-bp02

swh-b921-nw01 

und1-bp03, und1-bp04, dmp1-bp01

...

This involves two Magnet IOCs.  The new magnet sofware must be a single image that works in IOCs that control the new fast correctors, and IOCs that do not.

Before April the network connections will have been tested as described above. After start-up we must schedule time for the following installation plan:

...

involves 18 BPM IOCs, and 2 BLEN IOCs.  Sonya pointed out that the undulator BPM IOCs do not have EIOCs so their network setups will be more like the Magnet IOCs ( NIC1 for Channel Access, NIC2 for FCOM).  I don't know if these different BPM types use different IOC images, but the goal should be to make a single image for IOCs used by feedback and those not. This is not an issue with BLENs - both BLEN IOCs are used by feedback.

Before April the network connections/switch configurations will have been tested as described above. After start-up we must schedule time for the following installation plan:

Controller IOCs

3 controller IOCs.  We should be able to install the Controller IOCs during the downtime, or really anytime before April. They may be useful for production network testing during the downtime - Terri and Ernest can plan to install the Controller IOCs with the network installations.

...

A version 2 of the BLD IOC needs to be installed once we have the 1) Bunch Charge Feedback, the 2) Longitudinal Feedback, and the 3) LTU Launch Feedback running and providing their States data over FCOM. This will not likely happen until later in the summer. We discussed that this IOCs NICs will be dedicated to 1) FCOM and 2)Photon Multicast network - leaving no NIC for Channel Access. Sheng to think about whether having Channel Access is necessary, and alternative ways to monitor this VME if there is no channel access.

ACTION ITEMS

  • Terri to make schedule for Network installation and test during downtime, with input from Sonya, Kristi, Kukhee, Sheng
  • Terri to add Controller IOC installation, with input from Ernest
  •