5) Scintillating screen
The camera setup is either the existing LFOV system or LUXE's includes a scintillating screen (Type ) and camera (Basler
) which can be positioned is placed before the Cherenkov detector.
- Camera placement:
- (x,y,z) = (-0.02, 0.669, 2016.6595) m (mounting screw location in facet coordinates, uncertainty of +/- 0.02 m)
- tilting angle of 36°
SiPM Power Supply
The SiPMs are powered via the Keysight E36234 from the electronics rack (FKG20-24) via a long BNC cable to the dump table.
...