That's a check to make sure that the LCLS1 fiducials are arriving on boundaries of 71kHz (any multiple of 1666 - 119 MHz clocks).
LCLS2
Upstream Timing Issues
This does not apply to LCLS1 timing, I believe.
...
One of these "outs" goes to a local fanout in 208, which then drives xpm0.
Triggers/Transitions Behaving Erratically
Saw this after an ACR timing system outage on May 22, 2024.
Transitions weren't transmitted from xpm3. Fixed-rate L1Accepts seemed to go in bursts. Dumped out xpm3 frames to log file with xpmpva. Saw that the readout group messages were stuck. Fixed with a TxLinkReset to xpm3 (from xpm0). May have also been fixed with an RxLinkReset in the xpmpva UsTiming tab of xpm3.
Trigger Delays
See also Matt's timing diagram on this page: Bypass Events
...