← GT Readout Platform Gliffy DiagramdisplayNamefiber-block-diagramname

  • Fiber part orders:
    • Jira
      serverSLAC National Accelerator Laboratory
      serverId1b8dc293-975d-3f2d-b988-18fd9aec1546
      keyTIDAT-526
    • Jira
      serverSLAC National Accelerator Laboratory
      serverId1b8dc293-975d-3f2d-b988-18fd9aec1546
      keyTIDAT-603
  • There are two possible options to connect the fiber between the GT Readout Platform digital board (on the left) and the PCIe card (on the right):
    • Direction connection:
      • This will connect all fibers in order from lane 0 to lane 11
      • The last step in the connection to the PCIe card allows to swap the lanes in groups of 4 if needed
    • LC breakout connection:
      • This will breakout all 24 individual fibers into a LC adapter panel
      • The connection shown in the diagram below is a direct one-to-one, but the adapter panel allows for full flexibility in swapping channels and moving them around
      • It also makes it possible to "inject" e.g. a timing fiber on one of the fiber lanes going to the GT Readout Platform

...

Image Added