Confluence will be unusable 23-July-2024 at 06:00 due to a Crowd upgrade.
...
Voltage measurements with analog and digital boards mated
|
| P24V0D | P24V0A |
---|
Boards 38-C00-01 39-C00-01 | Analog board | 23.96 V | 24.01 V |
---|
Digital board | 23.96 V | 24.01 V |
---|
Power supply current | 170 mA | 0.2 mA |
---|
{"serverDuration": 80, "requestCorrelationId": "266d47122d2db17d"}