The ePixHR250M 2x2 Camera is also using the LEAP transceiver for the optical links and the GT Readout Platform was based on the clocking structure that was used there with a SI5345B jitter attenuator and a LMK61E2 programmable clock. The table below tries to compare the two projects to highlight any commonality and differences between them:
- Both projects have have a 371.428571 MHz clock for the GTY
- Both projects have a 156.25 MHz clock with a SI53340 clock buffer with 2x outputs going to the GTY and 1 output to the SI5345B
- GT Readout has another output to a secondary SI5345B
- ePixHR250M has test pads for the remaining output
- Both projects have a SI5345B driven from a LMK61E2, a 48 MHz crystal or a clock output from the FPGA. A clock feedback loop is also used
- GT Readout has 3x outputs going to the GTY
- ePixHR250M has 2x outputs going to the GTY
GT Readout Platform | ePixHR250M |
---|
Image Modified
| Gliffy Diagram |
---|
| |
---|
size | 300600 |
---|
displayName | ePixHR250M-2x2-Camera-clock-structure |
---|
name | ePixHR250M-2x2-Camera-clock-structure |
---|
pagePin | 6 |
---|
|
|