Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Week Ending 12/24/2023

Removed posts for DM bypass. Removed unknown post holders from the laser path. Removed all unused optomechanics from the optical table.

Week Ending 12/10/2023

Wired up the S20 Launch mirror to the laser room picomotor controllers, the task was made difficult by a bunch of bad picomotor extension cables in the trailer. The picomotor now appears in the laser control panels for S20Launch http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2023/49/06.12&pos=2023-12-06T16:07:12

Week Ending 11/12/2023

Realigned the laser to all irises. Reset auto aligner target positions to match the nominal alignment through the irises. Changed the auto aligner to only use MainampNear in the auto aligner. http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2023/45/09.11&pos=2023-11-09T22:47:29

...