Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Week Ending 11/12/2023

Realigned the laser to all irises. Reset auto aligner target positions to match the nominal alignment through the irises. Changed the auto aligner to only use MainampNear in the auto aligner. http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2023/45/09.11&pos=2023-11-09T22:47:29

Realigned the SAGAs into the main amplifier to fix the bad profile on S20Launch, main amp output up from 450mJ to 648.4m . http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2023/45/08.11&pos=2023-11-08T15:00:47

Week Ending 10/29/2023

Used the DM to adjust the collimation of the laser which seems to have changed after the oscillator was fixed.

LCLS lasers fixed the oscillator which had dropped out of modelock. http:/

...

/physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2023/43/27.10&pos=2023-10-27T23:30:58

Replaced first filter (ND2) on S20 launch with an ND1 to use more of the cameras dynamic range.

...

Turned up SAGA voltages to get the main amp output back over 600mJ. http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2023/43/25.10&pos=2023-10-25T15:43:24

Week Ending 9/

...

24/2023

Adjusted main expanding telescope spacing from 120um to -440um to collimate the fiber laser in the tunnel. http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2023/38/19.09&pos=2023-09-19T23:55:40

Week Ending 9/

...

10/2023

Swapped both lens in the main expanding telescope to bring the beam back up to 40mm diameter (1/e^2) in the tunnel. http://physics-elog.slac.stanford.edu/facetelog/show.jsp?dir=/2023/36/06.09&pos=2023-09-06T23:34:39