Power-on the tixel computer (the equivalent of cmp005) with the fiber unplugged, then we plugged in the fiber and it didn’t lock until we did xpmmini→lcls2. It appears that yanking the timing fiber can cause disturbances in the system, but they are not repeatable 100% of the time. XPMs Power spikes can set the DAQ in a behavior similar to the XPM glitch, but only if pyxpms are running. To be repeated.

Upgrading XPM firmware seems to have mitigated all the issues (to 3.6.0 from 3.5.4). The bucket issue becomes more prominent, probably because other issues are not happening. This issue appears when power cycling the xpm11. Also, xpmmini issue could appear when connecting already powered up nodes.


in 2023/11/27

testing double offence.
rebooting a node with cameralink without the fiber connected and connect the fiber after

actionissue foundstatremedy
rebooting cmp005 with timing fiber disconnected from xpm, then connect fiber when cmp is back on linenone0/5xpmpva does not see the opal until the daq is booted up. No ISSUES.

Brainstorming Session

Nov. 16, 23 with mona, dan, weaver, caf, claus, melchior, cpo

...