facet home → Profile Monitor → LI20 → SPEC LINE GUI
New SPECLINE GUI (Fall 2023):
- Leave big "Dipole" switch in "Without" setting (dipole energy is not adjusted)
- Set "Z Object" to the position where the beam should be imaged, e.g., the center of the PB
- Set "Z Image" to the position of the screen, e.g., z=2015.26 for DTOTR
- Note: You can select from a few preassigned beamline locations with the dropdown menu, or, select "custom"
- M12, M34: transfer-matrix elements (set both to 0 for re-imaging)
- Energy: determines where the focus is
- Press "Calculate and Trim"
- ATTENTION: there is no possibility to calculate without actually changing the magnets. There will be no elog entry! (2023, Nov 17)
- Note - the "Trim" button does not do anything yet.
Dump table motors and filters:
IP2 Table on LI20 Profile monitor page:
Provides easier access to the dump table flippers (DTOTR1/2, LFOV) and motors.
Scripts for dealing with the spectrometer
...