Stage | IOC | PV | Cabling | Parameter Manager Config | Status | Newport UTS150PPV6 | ioc-mec-ppl-xps2 | MEC:PPL:MMN:13 | Standard Newport connection from mcn-mec-tch2. | OK | Micos 6237-C002 Linear Stage, 40mm travel, HV, VSS-42 motor, 16:1 VPGL gear Reference: https://www.pi-usa.us/en/products/precision-motorized-linear-stages | ioc-mec-usrppl-ims | MEC:USR:MMS:25 (formerly XTCS Rotation) | PR60 Patch Panel - DB9 Flange Connection "#4" - Stage. Using cable labeled "RS 422 Rotation Stage". Note: Not connecting DB9 from Micos stage containing limit switch information. | Micos_6237 | ioc-mec-usrppl-ims | MEC:TC1:MMS:22 (formerly XTCS Filter Wheel) | PR60 Patch Panel - DB15 Flange Connection "5" - Stage | VT-50-100 | PM: We have verified the cabling for the VT50 out to the cable that comes from the stage. Even when using a VT50 parameter set verified from CXI we saw no motion of the stage.Suggest mechanical inspection. UPDATED: Verified working as of 12/09/23 with Eric and Hae Ja. Solution was using the labelled VT50L cables connected to port 5 on the patch panel. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Detector Configuration
Detector | DAQ Host | DAQ Configuration | Cabling | Status |
---|---|---|---|---|
Epix10kaQuad0 | daq-mec-pgp02 | -i 0 -P 0x10 -R 0 -D 0x1760 | Host card 0 - (via overhead cable tray) - back of PR60 - PR60 patch panel - Flange - - Detector | OK |
Epix10kaQuad1 | daq-mec-pgp02 | -i 1 -P 0x20 -R 0 -D 0x1760 | Host card 0 - (via overhead cable tray) - back of PR60 - PR60 patch panel - Flange - - Detector | OK |
Epix10kaQuad2 | daq-mec-pgp02 | -i 2 -P 0x11 -R 0 -D 0x1760 | Host card 1- (via overhead cable tray - back of PR60 - PR60 patch panel - Flange - Detector | OK |
Epix10kaQuad3 | daq-mec-pgp02 | -i 3 -P 0x21 -R 0 -D 0x1760 | Host card 0 - (via overhead cable tray) - back of PR60 - PR60 patch panel - Flange - Detector | OK |
| ||||
Epix10ka_1 | daq-mec-cam01 | -i 0 -T -P 0x20 - R 0 - D -x1770 | Host card 0 - R60 E33 RHS patch panel (connection #3) - (via overhead cable tray) back of PR60 - PR60 patch panel - Test Flange - Detector | DAQ/IT issues with high UDP packet oss rates on 10Gb fiber connection to DAQ. |
Von Hamos Configuration
Components:
...
Requires Windows machine connected to ICS subnet.Windows PC- Replaced PC with Raspberry Pi
- The Ii is connected to port 13 of stack 8
- The IP address was already set as 172.21.46.200. You can login with username fifteen and password *LCLS*MEC*
...
Zyla | ||||
Alvium |
...