Confluence will be unusable 23-July-2024 at 06:00 due to a Crowd upgrade.
...
Requirement | Parameters | ||
---|---|---|---|
Power supply | 24V consistent with the HR detector | ||
Mechanical size | We would like to match the ePixHRM board dimensions to reuse cooling Side entrance detector
| ||
Digital board | 2.56x5.265" | ||
Power and communication | 2.56x5.240" | ||
Carrier | 2.56x1.95 | Can we do it smaller? What is the minimum amount of components that need to leave in this board | |
Expand | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL = 13 * 4(n.Asics) + 9 + 70 + 30 = 161 out of 96 HD, 416 HP |
System level power requirements for carrier (what are the specs for the voltage regulator and what is the number of regulators per power)
...