Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

    1. First, on the 2nd floor, the beam has only 3.5 passes by bounce mirrors (Fig. 3 a), insert the mirrors on the magnetic mount (Fig. 3 b) and send the beam to the compressor. Check and move the stage to the position marked by yellow "LP bypass MPA2" (Fig. 3c). Use the irises to check the manual delay.

    2. On the 1st floor (Fig. 2 b), check camera TT out and use the T2 mirror on the 2nd floor to adjust. Use the T3 mirror to point the beam to the output iris. Check and move the delay stage to the position marked by yellow " LP bypass MPA2" (Fig. 3 d).

    3. The beam should be on time tool GigE cam already. Use T3 mirror to adjust the beam on time tool GigE cam.
    4. To check pulse duration, flip in the 1" mirror to send the beam into Spider. (Fig 2 d) How to operate Spider

Image Modified


Image Modified


Image Modified


Figure 3 (a) on the 2nd floor, the beam has only 3.5 passes by bounce mirrors,  Figure 3 (b) insert the mirrors on the magnetic mount (Fig. 3 b) and send the beam to the compressor.Figure 3 (c) check and move the manual stage to the position marked by yellow "LP bypass MPA2" Figure 3 (d) check and move the remote delay stage to the position marked by yellow " LP bypass MPA2"

...