Page History
...
The XPM may be configured to insert event codes 272-287 into the timing stream. Four event codes are generated by each sequence engine within the XPM. The XPM has 4 sequence engines allowing 16 event codes total.
Engine | Event Codes |
---|---|
0 | 272-275 |
1 | 276-279 |
2 | 280-283 |
3 | 284-287 |
A current example for doing this is done by executing:
...