Spreadsheet from Dan VanWinkle on how to keep 16 MV when we lose one RF
station. (May 2007). All values are in KV.
Station Station | Voltage Future Voltage | If 2 Cav Park | If 4 Cav Park | Park HR81 7/13 |
---|---|---|---|---|
HR41 | 1200 | 0 | 1400 | 1350 |
HR46 | 1100 | 1350 | 1400 | 1360 |
HR81 | 2100 | 2150 | 2400 | 0 |
HR83 | 2200 | 2200 | 0 | 2400 |
HR85 | 2200 | 2200 | 2400 | 1200 |
HR21 | 1200 | 1350 | 1400 | 1400 |
HR22 | 1200 | 1350 | 1400 | 1400 |
HR23 | 1200 | 1350 | 1400 | 1400 |
HR24 | 1200 | 1350 | 1400 | 1400 |
HR25 | 1200 | 1350 | 1400 | 1350 |
HR26 | 1200 | 1350 | 1400 | 1400 |
Total | 16000 | 16000 | 16000 | 15660 1600 |
Total Voltage
4 Cavity stations at 2400 KV or 600 KV/Cav
2 Cavity stations at 1200 KV or 600 KV/Cav
...