Detector Number | Type | Function | In DAQ? | Notes | Cabled? | Running? | Comments | |
---|---|---|---|---|---|---|---|---|
1 | ePix100a | XRTSsingle photon diagnostics | Yes | in-vac | Yes | etch 12; vertical holder Q0 ePix0 Q2 fibers/PDU | ||
2 | ePix100a | Kalpha User spectrometersingle photon diagnostics | Yes | in-vac | No | Yes | etch 25; horizontal holder Q1 Not in TC yet. Q3 fibers/PDU | |
3 | ePix100a | single photon diagnosticsXRTS | Yes | in-vac | Yes | No | ePix0 Q2 etch 12; vertical holder Q0 fibers/PDU Recovering from water spill. | |
4 | ePix100a | Kalpha User spectrometersingle photon diagnostics | Yes | in-vac | Yes | etch 25; horizontal holder Q1 Q3 fibers/PDU | ||
5 | Zyla | MXI | Yes | in-air | zyla_xray_east Restart procedure at Zyla and iStar confluence page. Host is daq-mec-cam02. | |||
6 | XTCAV | Yes | in-vac |
...
ePix100a Kalpha → Q3 fiber & PDU S3fiber mapping is currently the same as for 4x quads. This needs to be changed!
Update on Fiber Mapping:
- Epix 1 - PR60 B1 #6 - R60 A3 #3
- Epix 2 - PR60 B1 #3 - R60 A3 #4
- Epix 3 - PR60 B1 #4
- Epix 4 - PR60 B1 #5
- Formerly used by focus_img opal.
- PR60 B1 #2 is the connection with black tape