Page History
...
cmp012 (timing) (close to the USB port) | cmp012 (data) (away from USB port) | cmp006 (timing) (close to the USB port) | cmp006 (data) (away from USB port) | 1: cmp022(away from USB port) 2: cmp022(close to USB port) 3: cmp023 (away from USB port) 4: cmp023 (close to USB port) | 1: cmp018(away from USB port) 2: cmp018(close to USB port) 3: cmp019 (away from USB port) 4: cmp019 (close to USB port) | 1: cmp009(away from USB port) 2: cmp009(close to USB port) 3: cmp017 (away from USB port) 4: cmp017 (close to USB port) | 1: cmp008 2: cmp010 3: cmp016 4: cmp025 | ||||
cmp011 (timing) (close to the USB port) | cmp011 (data) (away from USB port) | 1: cmp024(away from USB port) 2: cmp024(close to USB port) 3: - 4: - | 1: cmp020(away from USB port) 2: cmp020(close to USB port) 3: cmp021 (away from USB port) 4: cmp021 (close to USB port) | 1: cmp029 2: cmp030 3: - 4: - | 1: cmp026 2: cmp027 3: cmp028 4: - |
...
TMO Hutch Fiber Connections
XPM 2 input on RTM | Rack 4 in TMO hutch, FODU2, Cassette 4, fibers 3-4 (a.k.a TMO2.4.3-4) | Note that cassettes 3 and 4 are swapped between rack 3/4 |
XPM 2 network connection | Rack 3, Cassette 3, fibers 23-24, goes to Rack 4 FODU 5, Cassette 4, fibers 23-24, goes to Rack 4 FODU 2 cassette 4 fibers 5-6 | Note that cassettes 3 and 4 are swapped between rack 3/4 |
Room 208 Fiber Connections
See FEE Alcove Fiber Cabling for description of which patch panel in 208 goes to which detector. Note that the fiber numbering on that page is different from here. On the FEE alcove page we number fibers left-to-right, then top-to-bottom. Here we use a better scheme: using the actual fiber numbers marked on the cassettes. We should convert the FEE-alcove page to use the better fiber-numbering scheme.
Source | Destination | Notes | |||
---|---|---|---|---|---|
room 208 ATCA crate switch optical fiber port 0 | SRCF LC cassette 4 (counting from 1, left to right) fibers 11/12 | 10Gb network to SRCF node (drp-srcf-cmp004?) | XPM 2 input on RTM | Rack 4 in TMO hutch, FODU2, Cassette 4, fibers 3-4 (a.k.a TMO2.4.3-4) | Note that cassettes 3 and 4 are swapped between rack 3/4 |
XPM 2 network connection Rack 3, Cassette 3, fibers 23-24, goes to Rack 4 FODU 5, Cassette 4, fibers 23-24, goes to Rack 4 FODU 2 cassette (TMO FODU 1, Cassette 4 fibers 5-6 | Note that cassettes 3 and 4 are swapped between rack 3/4 | ) | ATCA switch optical port 7 counting from 0 | ||
Timing output Output of XPM2 in 208 | TMO FODU 1, Cassette 3, Fibers 17-18: 1.3.17-18 | Cassette 1 is missing | |||
Output Timing output of XPM3 in 208 | RIX FODU 1, Cassette 1, Fibers 7-8: 1.1.7-8 | ||||
XPM0-AMC0-PORT0 | RIX 1.1.3-4 | This is XMP0 → XPM3 in RIX, FODU 1 for RIX is FODU 5 in 208 | |||
XPM0-AMC0-PORT1 | TMO 2.4.3-4 | This is XMP0 → XPM2 in TMO, FODU 2 for TMO is FODU 7 in 208 | |||
XPM5-AMC0-PORT0 | RIX 1.1.3-4 | This is XPM3→ XPM5 | |||
XPM6-AMC0-PORT0 | TMO 1.3.17-18 | This is XPM2→ XPM6 | |||
TMO ATM CAMLINK | TMO FODU 1 cassette 3 fiber 1-2 (a.k.a. TMO1.3.1-2) | cassette 1 is missing | |||
RIX FIM MR4K2 | RIX FODU 1 cassette 1 fibers 25-26 (a.k.a RIX1.1.25-26) | ||||
RIX FIM MR3K2 | RIX1.1.27-28 | ||||
RIX FIM CHEMRIX | RIX1.1.29-30 | ||||
TMO FIM1 | TMO1.3.5-6 | Not sure which FIM this really corresponds to in TMO | |||
TMO FIM2 | TMO1.3.7-8 | Not sure which FIM this really corresponds to in TMO | |||
RIX HSD2 | RIX1.1.19-20 | I may be swapping hsd2/3 (this was FEE fodu 1.3.18, old numbering scheme) | |||
RIX HSD3 | RIX1.1.23-24 | I may be swapping hsd2/3 (this was FEE fodu 1.3.15, old numbering scheme) | |||
TMO CAMLINK OPAL1 | TMO1.4.1-2 | ||||
TMO CAMLINK OPAL2 | TMO1.3.3-4 | ||||
TMO CAMLINK FZP | TMO1.2.11-12 | ||||
RIX CAMLINK ATM | RIX1.3.13-14 |
...