- which fibers should be MPO vs LC?
- only use MPO for fim's.
- should we fanout timing at SRCF or put it through the bos? (related question: should camlink devices go through the bos?)
- use the fanouts at SRCF for simplicity
- don't maybe put camlink fiber through the bos for now?
- routing mono-encoder udp network over to srcf
- sharing xtcav between hutches with bos-switchable timing
100kHz data volumes:-
- wave8: 8waveforms*256samples/sample*2bytes/sample*0.1MHz = 400MB/s
...
- (need to add FEX data too)
...
- piranha: 2048px*2bytes/px*0.1MHz=410MB/s
...
- hsd full wf: 60000samples*2bytes/sample*0.1MHz = 12GB/s
...
- max waveform length appears to be ~60000 samples looking at xtc2 file?
...
- FEX needs to reduce it to 4GB/s (3x)
...
- bld: 336bytes/event*0.1MHz = 33MB/
...
- s (from xtcreader -f /cds/data/psdm/prj/public01/xtc/tmoc00118-r0222-s008-c000.xtc2)
...
- timing: 309bytes/event*0.1MHz = 31MB/s
recabling proposal:
- tmo timing (including pvadet, bld) (LC to fanout)
- rix timing (LC to fanout)
- (4) tmo camlink nodes (LC)
- (2) rix camlink nodes (LC)
- tmo/rix fim node (5 fims) (MPO)
- (2) rix hsd nodes (LC)
- (7) tmo hsd nodes (LC)
- peppex hsd node (LC)
- (2) tmo/rix ami
- (2) tmo/rix teb
- (2) tmo/rix mebuser
- xtcav
- mono-encoder
...