  • which fibers should be MPO vs LC?
    • only use MPO for fim's.
  • should we fanout timing at SRCF or put it through the bos? (related question: should camlink devices go through the bos?)
    • use the fanouts at SRCF for simplicity
    • don't maybe put camlink fiber through the bos for now?
  • routing mono-encoder udp network over to srcf
  • sharing xtcav between hutches with bos-switchable timing

100kHz data volumes:-

  • wave8: 8waveforms*256samples/sample*2bytes/sample*0.1MHz = 400MB/s

...

  • (need to add FEX data too)

...

  • piranha: 2048px*2bytes/px*0.1MHz=410MB/s

...

  • hsd full wf: 60000samples*2bytes/sample*0.1MHz = 12GB/s

      ...

        • max waveform length appears to be ~60000 samples looking at xtc2 file?

      ...

        • FEX needs to reduce it to 4GB/s (3x)

      ...

      • bld: 336bytes/event*0.1MHz = 33MB/

      ...

      • (from xtcreader -f /cds/data/psdm/prj/public01/xtc/tmoc00118-r0222-s008-c000.xtc2)

      ...

      • timing: 309bytes/event*0.1MHz = 31MB/s

      recabling proposal:

      • tmo timing (including pvadet, bld) (LC to fanout)
      • rix timing (LC to fanout)
      • (4) tmo camlink nodes (LC)
      • (2) rix camlink nodes (LC)
      • tmo/rix fim node (5 fims) (MPO)
      • (2) rix hsd nodes (LC)
      • (7) tmo hsd nodes (LC)
      • peppex hsd node (LC)
      • (2) tmo/rix ami
      • (2) tmo/rix teb
      • (2) tmo/rix mebuser
      • xtcav
      • mono-encoder

      ...