The firmware requirements are derived from requests that come from the ASIC, detector and DAQ subsystems. The goal of defining them is to communicate among the design team and support teams which feature must be present and why and therefore establish a communication platform.



Requirement numberDescriptionMetric of successStatus
ASIC


ASIC 1.0Generate wareforms to control ASIC data acquisition (i.e. R0, ACQ, GR, SRO, CLK, DigRST, etc)Waveform generated by the FPGA matches ASIC specs
ASIC 1.1Receive and decode data with stream auto tuningReceive encoded data, with the firmware finding the best eye delay position automatically
ASIC 1.2Data decode using 16b20b to retrieve SoF, Eof, and real dataData decoded can be used to generate image packets
ASIC 1.3Program each ASIC individually using SACI bus

ASIC 1.4Provide external DAC 20bit voltage source to check ASIC ADC performance. (This allows to fine tune Pipo delay)

ASIC 1.5Two trigger operation should be available. Run Triggers generates a frame but does not send data. Run Triggers followed but DAQ triggers generates a frame and sends data to DAQ. This two trigger operation allows for system level thermal stabilization

ASIC 1Allow ASIC power supplies to be turned on and off via registers

ASIC 1Monitor ASIC analog outputs (for the ASIC where this feature is available) and stream the data as a "pseudo" scope

























DATA


DATA 1.0Data packet should be created with a 4 ASIC to one packetFW demonstrate implemented 4 to 1
DATA 1.1Data packed should be added by a header containing acquisition number, ID

DATA 1.2Data descrambling, image should be reagentes in FW such that each 4 x 1 ASIC data shout is receiving with physical meaning (in software a single matrix reshape should be enough to display the 4x1 ASIC image correctly)













DAQ


DAQ 1.0Serial number of each carrier, digital board and analog board should be readout and available via register access

DAQ 1.1Timing module should be part of the FW, where trigger information and timestamps are received

DAQ 1.2Monitor environmental variables (temperature, humidity and selected voltage and currents based on board specific schematics)

DAQ 1.3Add to the data packed the trigger information. This should be implemented with surf module  

DAQ 1.4










  • Image header description

Add a table hear with new header description

...