Rack map link

  • Removed (partially) the HV/LV patch panel in PR62 and the associated and unused Weiner power supply found in rack R64B. The latter has EEIP approval.
Item descriptionLocationPerson who entered the entryServiceNow ticket linkCompleted?Comments
JJ slitsOptical Table in the hutchLCLS0003627Work assigned to Brian Smith. The controller is now back at XPP (9 June 2022) and a comment indicated as such added to the ServiceNow ticket. 

Missing EEIP stickers

(4 copies of #3532)

edrive?1

edrive?2

Peregrine McGehee 

Peregrine to create ServiceNow ticket.

Replace peeling EEIP sticker

(1 copy of #1152)

S65Peregrine McGehee 

Peregrine to create ServiceNow ticket.
CXI ControllerPR63, Back, E8/E9Peregrine McGehee 

PR63 was inherited from CXI.

HV/LV Supply

B999-PR62-PPL-06

261-510-53-00

PR62, E6/E7

Note from Eric Cunningham: I'm fairly certain there's nothing plugged into it, and I think it's sourced from a supply in rack 64B that also has nothing plugged into it. It would be a great candidate for removal -- free up space in both racks (PR62 and 64B)!

We will examine this during the 10 June 2022 10:00 cable session.

MEZZPeregrine to inspect MEZZ Racks on 10 June 2022.